PH Meter 0.01 High Precision for Water Quality Tester with 0-14 Measurement Range Suitable Aquarium Swimming Pool

$2.80

 

WHOLESALESold in bulk only
  • Minimum order50 pcs / SKU
  • Reference price$2.80 / pc
  • Mixed batchesAccepted
  • PaymentBank transfer (T/T)
Quantity pricing
Order quantityTier discountUnit price
50 – 199 pcsList price$2.80 / pc
200 – 499 pcs−5%$2.66 / pc
500 – 999 pcs−8%$2.58 / pc
1,000+ pcs−12%$2.46 / pc
Request a quote for 50+ pcs

Final price includes your consolidated freight share and is confirmed in writing before payment.

Wholesale pricing · minimum order applies · no single-piece sales
SKU: 1005001772116229 Category: Tags: ,

Description

Bulk Buy PH Meter 0.01 High Precision for Water Quality Tester with 0-14 Measurement Range Suitable Aquarium Swimming Pool

  • Brand Name: LPPCOLTD
  • Certification: CE
  • Origin: CN(Origin)
  • With Backlight Or Not: NO
  • Is Smart Device: NO
  • Model Number: PH-02
  • Display Type: DIGITAL
  • item name: ph meter
  • Color: yellow
  • PH buffer power: 4.00&6.86&9.18
  • battery: 2 pcs lr44 not including
  • pH Value: 0.00-14.00
  • Using range: ph meter for water and Aquarium and Laboratory and pool etc

PH Meter 0.01 PH High Precision Water Quality Tester with 0-14 PH Measurement Range, Suitable for Aquarium, Swimming Pool, Indoor Outdoor

Digital PH Meter Water Tester

It’s not only ideal for household or laboratory use, also suitable for testing pH balance of drinking water, pool, aquarium, food Project, RO system, Spa, or hydroponics.
Specifications:
► Measuring range: 0.00-14.00 pH
► Resolution: 0.01 pH
► Accuracy: 0.01 pH
► Batteries: 2X 1.5V LR44 (not included)
► Automatic temperature compensation: 0-50Centigrade(32-122It)
► Dimensions: 15×2.5×1.3cm/6×1.1×0.5 inch
► Net Weight: 52g/1.83 oz
Warm tips
It STEP 1: Turn open pH meter, Clean the electrode in distill water
It STEP 2: Immerse the electrode in pH 6.86 standard buffer solution
It STEP 3: Press the “CAL” button. Wait until the display digital is 6.86pH and steady
It STEP 4: Clean the electrode in distill water and dry it, immerse the electrode in Ph 4.00 standard buffer solution
It STEP 5: Press the “CAL” button. Wait until the display digital is 4.00pH. Then complete pH 4.00 calibration
It STEP 6: Clean electrode and dry it, put the meter into PH 9.18 standard buffer solution. Check if reading is correct between 9.17-9.19pH

Instructions for use of PH calibration powder:
Calibration powder: pH standard solid substance. It can be used after adding water. Suitable for the calibration of any type of ph meter. Each package can prepare 250ML standard solution.

(Be sure to add water according to the required ratio, otherwise it will affect the accuracy of the calibration and increase the error)

Precautions:
Please note that the PH pen probe is a glass product and is a fragile product. Please do not collide with things. Once the damage is not replaceable, you must protect the probe. After use, use absorbent paper to gently absorb the water on the probe.

Matters needing attention:
PH meter has been calibrated before delivery, the buyer does not need to re-calibrate after receiving the goods!

In the following cases, the PH meter must be re-calibrated:
1. Has been used for a long time after calibration;
2. Special electrode use Frequently;
3. The measurement accuracy requirements are relatively high.

Standard configuration:
1XPH meter with opp bag
3X calibration powder
1X instruction manual

Questions & Answers:

1. Q: How often should I calibrate my ph meter pen ?

A: One calibration can last for about half a month. When the electrode exposed to air for extended period of time, users should calibrate it. When testing polluted water quality, more frequent calibration is required to ensure the accuracy of the test value

2. Q: Can I test two kinds of water without calibrating ?

A : Yes , but when testing the liquid that is not pure water or distilled water, after the test, you need to put it in pure water or distilled water, wash it and wipe it dry, and then test the next liquid (to ensure the accuracy of the value of the next test liquid)

3. Q: Why my ph meter switch and digital display are not sensitive ?

A: It might be caused by low battery. Just replace the battery and it will work again.

4. Q: Can I use this to test Urine ?

A: Yes , it can. The test liquid must not be corrosive, which will damage the accuracy of the glass probe and shorten the service life of the glass probe.

5. Q: What if the calibration result is wrong?

A: Assuming that the calibration result is wrong, the pen recognizes ph 9.18 or ph 4.01 after calibrating ph 6.86 .

Step 1: Take 50ml of purified water or distilled water, and then import one pack of 6.86 calibration powder, stir evenly, put the PH pen probe in water for One Hours.

Step 2: Then turn on the pen, press and hold the CAL button for five seconds, then let go, the value flashes, and the END calibration is completed.

Except the ways above, you could long press the switch and calibration keys at the same time for five seconds, restore the factory settings, and then test.

( The test difference might within 2% with reset control , and the powder calibration’s test difference is within 0.1%-1% )

Additional information

Weight 0.02 kg

Reviews

There are no reviews yet.

Be the first to review “PH Meter 0.01 High Precision for Water Quality Tester with 0-14 Measurement Range Suitable Aquarium Swimming Pool”

Your email address will not be published. Required fields are marked *